Fire Survival Resistant Cables

Home / Products / Fire Survival Resistant Cables

Welcome to Best Cable Solutions Center

Fire Survival Resistant Cables

Spectrum Cable-Tech has added a special range of fire survival cables to the product range that are designed to continue to operate for a defined minimum period of time in case of fire including water spray & mechanical shock. Request For More Fire Survival Resistant Cables
Overview
Technical Details
Sales & Support

Spectrum Cable-Tech has added a special range of fire survival cables to the product range that are designed to continue to operate for a defined minimum period of time in case of fire including water spray & mechanical shock.

Conductor

Electrolytic Grade Copper Bare/Tinned, Solid/Stranded Annealed Flexible Conductors conforming to IS:8130:1984 or another international standard.

Fire Barrier

Conductors are insulated with Mica Glass Tape/silicone rubber as per requirements. Mica Tape survives temperatures up to 1000°C. It is non-toxic, chemically neutral, and 100% Halogen free.

Primary Insulation

The Insulated material may be Heat Resistant PVC/XLPE/Silicon Rubber or any other dielectric material as per customer specification.

Screening

Individual & Overall Shielding may be of Annealed Tinned Copper Braiding/Poly Aluminum [Thin Layer of Aluminum Foil bonded to Polyester Film] Tape with Annealed Tinned Copper Drain Wire. Braiding ATC Shield has high tensile Strength and provides better coverage in flexing applications.

Inner Sheath

The Inner Sheath is applied over laid-up of cores by extrusion/wrapping of thermoplastic material. The Insulation and Inner Sheath can be Normal Pvc /FR PVC / FRLS PVC / ZHFR / LSF Compound depending upon their application or specification.

Armour

Armour is applied over the inner Sheath. It may consist of galvanized Round Steel wires or galvanized Flat Steel Strips conforming to IS:3975.  Steel wire armoured cables are suitable for direct burial. One or more copper wires can be incorporated into the armour to increase the conductivity of the armour where it is being used as an earth return. Armour can also by steel tape/double helical steel tape or aluminum wire if the client’s requirement. Round Wire armoring is provided where the calculated diameter under Armour is 13.0 m.m. Above this, armoring is either round wire/steel strip as per the client’s requirement.

Outer Sheath

A final covering of PVC Compound is applied over armouring in case of armoured Cable or over the Inner Sheath in case of unarmoured Cable. The Color of the Sheath is Black, Grey, or as per the customer’s choice. The Outer Sheath material may be FR PVC/FRLS PVC/ZHFR/LSF as per the requirement of the specification.

Standard Specifications

ICE 331/ BS 6387 :1994, IEC 60331, BS 6387 – CAT A,B,C,W,Z BS 7846 – CAT F1, F2, F3 & other customized & international standards.

Characteristics

  • Will withstand the Flame temperature of 750 degrees centigrade up to 3 hours without electrical breakdown at rated voltage.
  • During fire conditions small quantities of toxic gases mainly, CO, and CO2 are inevitably emitted. Fire Survival Cables are designed to limit these toxic gases within the safety level.
  • Corrosive Gases react with moisture to produce active acids which corrode metals causing extensive long-term damage. Often these gases spread throughout the building through the ventilation system or within the entire installation. This is particularly damaging to electronic equipment and even to exposed steel structures or even the concrete-enclosed steel structures.
  • Does not propagate flame.

Typical Application:

These fire retardant cables specially designed for to maintain long-term circuit integrity during and after a fire like public address and emergency voice communication systems, fire extinguishing systems, sprinklers pumps, control panels, exit lights in high-rise building control and instrumentation services in industrial, commercial and residential complexes, hospitals, airports, malls and crowded areas etc. data and voice transmission, CCTV, security, smoke detection and evacuation monitoring applications, interconnection of distribution boxes and end devices, where continued functionality is required during a fire situation, in high-temperature installation conditions.

 

Construction Single Core / Pair / Triad and Multi Cores / Pairs /Triads
Voltage Grade 600/1100 VAC
Conductor Stranded or solid annealed bare or Tinned Copper Conductor
Fire Barrier Glass mica tape
Insulation Silicone rubber or Cross linked polyolefin elastomer
Screening Individual and/or overall with following options – – Aluminum Mylar/Copper Tape with Tinned Copper Drain Wire – Braided with Bare or Tinned or Nickel Plated or Silver Plated Copper
Inner Sheath PVC / HRPVC / FRPVC / FRLS PVC/ ZHFR / LSF / PTFE / Fibre Glass
Inner Sheath LSOH / ZHFR or equivalent
Armouring Galvanized Steel wire/strip or wire braiding
Outer Sheath LSOH / ZHFR or equivalent
Standards-BS 5308 or equivalent with fire resistance to BS: 6387 category CWZ
IEC 60331 tested for 950°C for 3 hrs

Contact Us For

Fire Survival Resistant Cables

For Sales, Price & International Trade

For Customized Manufacturing & Technical Details

Request For More Fire Survival Resistant Cables

Leading Manufacturing Of Wires & Cables

Spectrum Wires & Cables are used all over the country by a wide spectrum of industries, in a great variety of applications.

Request For More Info